|   APTIV™ FILMS 1102  |  
|   APTIV 1100 series films are the mineral filled semi-crystalline films made from VICTREX™ PEEK polymer. The film provides a material solution for engineers in ultra-high performance applications.  |  
| Material Properties | |||
| Physical |   Nominal Value  |    Unit  |    Test Method  |  
|   Density (23°C)  |    1.45  |    g/cm³  |  ISO 1183 | 
|   Water Absorption 1 (Equilibrium, 23°C, 0.0500 mm, 50% RH)  |    0.080  |    %  |  ISO 62 | 
|   Shrinkage 2  |  |||
|   MD : 200°C, 50.0 µm  |    < 0.50  |    %  |  |
|   TD : 200°C, 50.0 µm  |    < 0.50  |    %  |  |
| Films |   Nominal Value  |    Unit  |    Test Method  |  
|   Film Thickness - Recommended / Available  |    12 to 125 µm  |    |  |
|   Tensile Modulus  |  ISO 527-3 | ||
|   MD : 23°C, 25 µm  |    5000  |    MPa  |  |
|   TD : 23°C, 25 µm  |    4500  |    MPa  |  |
|   MD : 23°C, 50 µm  |    4800  |    MPa  |  |
|   TD : 23°C, 50 µm  |    4300  |    MPa  |  |
|   MD : 23°C, 100 µm  |    4500  |    MPa  |  |
|   TD : 23°C, 100 µm  |    4200  |    MPa  |  |
|   Tensile Stress  |  ISO 527-3 | ||
|   MD : Break, 23°C, 25 µm  |    100  |    MPa  |  |
|   TD : Break, 23°C, 25 µm  |    80.0  |    MPa  |  |
|   MD : Break, 23°C, 50 µm  |    100  |    MPa  |  |
|   TD : Break, 23°C, 50 µm  |    80.0  |    MPa  |  |
|   MD : Break, 23°C, 100 µm  |    100  |    MPa  |  |
|   TD : Break, 23°C, 100 µm  |    80.0  |    MPa  |  |
|   Tensile Elongation  |  ISO 527-3 | ||
|   MD : Break, 23°C, 25 µm  |    > 100  |    %  |  |
|   TD : Break, 23°C, 25 µm  |    > 10  |    %  |  |
|   MD : Break, 23°C, 50 µm  |    > 100  |    %  |  |
|   TD : Break, 23°C, 50 µm  |    > 10  |    %  |  |
|   MD : Break, 23°C, 100 µm  |    > 100  |    %  |  |
|   TD : Break, 23°C, 100 µm  |    > 10  |    %  |  |
|   Trouser Tear Resistance 3  |  ISO 6383-1 | ||
|   MD : 50 µm  |    6.00  |    N/mm  |  |
|   TD : 50 µm  |    7.00  |    N/mm  |  |
|   Puncture Resistance (23°C, 50.0 µm)  |    5  |    kJ/m²  |  Internal Method | 
| Thermal |   Nominal Value  |    Unit  |    Test Method  |  
|   CLTE - Flow 4 (0.0500 mm)  |    3.5E-5  |    cm/cm/°C  |  ASTM D696 | 
|   Thermal Conductivity  |  ASTM E1461 | ||
|   -- 5  |    0.43  |    W/m/K  |  |
|   -- 6  |    0.91  |    W/m/K  |  |
| Electrical |   Nominal Value  |    Unit  |    Test Method  |  
|   Volume Resistivity 7 (23°C, 50 µm)  |    1.0E+16  |    ohms·cm  |  ASTM D257 | 
|   Dielectric Strength 8 (23°C, 50 µm)  |    200  |    kV/mm  |  ASTM D149 | 
|   Dielectric Constant (23°C, 50 µm, 10 MHz)  |    3.6  |    |  ASTM D150 | 
|   Dissipation Factor (23°C, 50 µm, 10 MHz)  |    1.0E-3  |    |  ASTM D150 | 
| Notes | 
| 124 hrs | 
| 2TM-VX-84 | 
| 323°C | 
| 4below Tg | 
| 5Through Plane | 
| 6In-Plane | 
| 7100 V | 
| 80.25 inch electrode | 